Goods of transport industry
The plant has designed and manufacture the turning-tilting units for the trams
They serve for:
Operating temperature mode | from -25º С to +35º С |
Thickness of the channelled shield | not less than 1,15 mm |
Coefficient of the shield heat transfer | from 2 kcal/m h º С |
Value of the shield sound insulation | not more than Rw = 14-15 dB. |
Material of the joint assembly floor | aluminium plate with the skid-resistant corrugation |
Possible curve section radius | 20 m |
The structure cycles a circle of radius (to the point that exposes the most) | from the outer part of the track – not more than 21.8 m |
from the inner part of the track – not less than 18.7 m | |
Maximum rotation angle left and right | not more than 20º |
Compliance with the requirements | complies with the State Standards of Ukraine DSTU UN/ECE R 36-03-2005 |